Industrial Ultrafiltration Spiral-Wound Element:
MT(PES 5kDa)
Synder Filtration’s Ultrafiltration Elements offer an optimal combination of both flux and rejection in a comprehensive range of MWCO’s. Contact us today to learn more about our complete line of membrane products and services.
MT is a slightly tighter version of the popular ST membrane and can be commonly used for similar applications. This particular PES-based ultrafiltration membrane is well-suited for whey protein (WPC/WPI) concentration and milk protein (MPC/MPI) concentration and purification. Enzymes, proteins, and plant extracts can also be separated and concentrated while allowing salts and excess water to pass through the membrane, increasing the product yields compared to conventional methods for these types of applications. Other applications outside of the dairy industry include endotoxin and pyrogen removal and protein/enzyme concentration in the biopharmaceutical industry, and gelatin production and egg white concentration in the food & beverage industry.
INDUSTRIAL SERIES BENEFITS
- Widest range of UF MWCO’s available
- Good resistance to pH and temperature
- High resistance to fouling
- Customizable dimensions for unique housings
COMMON APPLICATIONS
- Whey protein concentrate & isolate
production - Enzyme concentration
Element Specifications
RECOMMENDED OPERATING PARAMETERS
Membrane Type | |
Proprietary PVDF | Spiral-Wound with netted outerwrap or fiber glass hardshell (FRP) |
Pressure | PSI | Bar |
Max Inlet Pressure | 116 | 8.0 |
Min Outlet Pressure | 10 | 0.7 |
Max Differential Pressure per Element | 18 | 1.2 |
Max Permeate Backpressure | 5 | 0.3 |
Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements.
Temperature | Fahrenheit | Celsius |
Max. Operating | 122° | 50° |
Max. CIP Temperature | 122° | 50° |
pH Parameters | pH |
pH Range during Operation at 25°C Max | 1.0-11.0 |
pH Range during CIP Operation at 50°C Max | 2.0-11.0 |
Peroxide | Max ppm. |
Free Peroxide in Product During Operation | <3 ppm |
Peroxide as a sanitizer at 25°C Max, pH6-7, 10minutes recirculation | 0.1% |
Chlorine | Norm PPM | Max PPM |
Free Chlorine During Operation | 0 | <0.1 |
Chlorine During CIP at pH10.8-11.0 and 50°C | 150 | 180 |
Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.
DIMENSIONS & WEIGHT
Element | Model No. | Diameter (B) in (cm) | Length (A) in (cm) | PWT ID/OD in (cm) | Tube Extension (C) in (cm) | Dry Weight lb (kg) |
1.8" | 1812TM | 1.8” (4.6) | 11.75” (29.8) | 0.665” (1.71) | 0.75” (perm) 1.00” (plug) |
1.0 (.45) |
2.5" | 2540TM 2540HF 2540HM |
2.4” (6.1) 2.4” (6.1) 2.4” (6.1) |
40.0” (101.6) 40.0” (101.6) 40.0” (101.6) |
0.75” (1.90) 0.625” (1.59) 0.75” (1.90) |
1.00” (2.54) – 1.00” (2.54) |
4.0 (1.8) 4.0 (1.8) 4.0 (1.8) |
4" | 4040TM 4040HM 4040HF |
3.9” (9.9) 3.9” (9.9) 3.9” (9.9) |
40.0” (101.6) 40.0” (101.6) 40.0” (101.6) |
0.75” (1.90) 0.75” (1.90) 0.625” (1.59) |
1.00” (2.54) 1.00” (2.54) – |
12.0 (5.5) 12.0 (5.5) 12.0 (5.5) |
8" | 7940HF 8040HF |
7.9” (20.1) 7.9” (20.1) |
40.0” (101.6) 40.0” (101.6) |
1.138” (2.89) 1.125” (2.86) |
– – |
35.0 (15.9) 35.0 (15.9) |
Recommended Element Cross Flow Rate
Element | Feed Spacer (in miles)
|
||||||||||
1.8" | m3/hr gpm |
0.7 3 |
0.8 3 |
0.9 4 |
1.0 4 |
1.1 5 |
|||||
2.5" | m3/hr gpm |
1.3 6 |
1.5 7 |
1.8 8 |
2.0 9 |
2.1 9 |
|||||
4.0" | m3/hr gpm |
3 15 |
4 17 |
5 20 |
5 23 |
5 24 |
|||||
8" | m3/hr gpm |
15 66 |
17 75 |
20 89 |
23 99 |
24 105 |
*Note: The recommended cross flow rate will be subject to differential pressure limitations and specific applications.
Membrane Area(SQ. FT.)
Element | Feed Spacer (in mils)
|
|||||||||
1812TM | 3.1 | 2.7 | 2.1 | 1.6 | 1.3 | |||||
2540M | 28 | 24 | 20 | 16 | 13 | |||||
2540F | 30 | 26 | 22 | 17 | 14 | |||||
4040M | 81 | 72 | 58 | 46 | 39 | |||||
4040F | 86 | 75 | 61 | 49 | 41 | |||||
7940F | 379 | 335 | 268 | 210 | 178 | |||||
8040F | 379 | 335 | 268 | 210 | 178 |
TECHNICAL NOTES
For element sizes not listed, please call or email Synder Filtration for details. We can design an element to fit your exact needs – just specify the element outer diameter (OD) or vessel/housing inner diameter (ID), element inner diameter (ID), and length. Elements are also available with or without a controlled bypass tail. Additional feed spacers are also available. Trials should be conducted to determine optimal application conditions.
Applications
Similar Membranes
questions? Fill out this form. We’ll contact you within 24 hours!
Resources
MEMBRANE RESOURCES
- Definition of a Membrane
- Membrane Materials: Organic vs. Inorganic
- Pressure-Driven Membrane Filtration Processes
- Concentration Polarization in Pressure-Driven Processes
- Degrees of Membrane Separation
- Flux Behavior in Membrane Processes
Module Configurations & Processes
-> View all membrane resources
TUTORIALS