Synder’s NFS nanofiltration membrane was developed specifically to meet requirements for seawater sulfate removal within the oil and gas industry. With a 30% increase in efficiency versus leading competitors, NFS offers excellent sulfate removal and potential reductions in nanofiltration footprint. The NFS membrane also has the lowest molecular weight cut-off in the entire nanofiltration line, with a range from 100 to 250 Daltons. Other common applications for this membrane include demineralization and concentration of lactose, whey concentration and deashing, and amoxicillin removal.
NF SERIES BENEFITS
- 30% increase in efficiency versus leading competitors and potential reduction in NF footprint
- Excellent MgSO4 and Na2SO4 rejection
- Operation at lower pressures than Reverse Osmosis membranes and still achieve excellent rejection of divalent and multivalent ions
- NF membranes greatly reduce levels of hardness, nitrates, sulfates, tannins, turbidity, color, TDS, and moderate levels of salt from feed water streams
Element Specifications
MEMBRANE SPECS
Model | Polymer | Approx. Molecular Weight Cutoff |
Typical Operating Flux |
Avg Na2SO4 Rejection1 |
Avg MgSO4 Rejection2 |
Avg NaCl Rejection3 |
NFS | Proprietary PA TFC | 100-250Da | 30-40 GFD | 99.7% | 99.5% | 50-55% |
1Test Conditions: 2,000ppm Na2SO4 solution at 110psi (760kPa) operating pressure, 77°F (25°C)
2Test Conditions: 2,000ppm MgSO4 solution at 110psi (760kPa) operating pressure, 77°F (25°C)
3Test Conditions: 2,000ppm NaCl solution at 110psi (760kPa) operating pressure, 77°F (25°C)
RECOMMENDED OPERATING PARAMETERS
Operating Parameters | |
Maximum Operating Pressure | 600psi (4,137kPa) if T < 95°F (35°C) 435psi (3,000kPa) if T > 95°F (35°C) |
Maximum Temperature | 50°C (122°F) |
pH Range @ Max Temperature | 3-9.5 |
pH Range @ Ambient Temperature | 3-10.5 |
Cleaning Parameters | |
Maximum Temperature (Short term <30min) | 50°C (122°F) |
pH Range @ Max Temperature | 2-11 |
pH Range @ Ambient Temperature | 2-11 |
Pressure Drop | PSI |
Maximum per Element | 15psi (103kPa) |
Maximum per Housing | 60psi (414kPa) |
Chlorine Tolerance |
500ppm hours, dechlorination recommended |
Element Dimensions & Weight
Element | Model No. | Diameter (B) in(cm) | Length (A) in(cm) | P.W.T. ID/OD in(cm) | Tube Extension (C) in (cm) | Dry Weight lb(kg) |
1.8" | 1812TM | 1.8"(4.6) | 11.75"(29.8) | 0.675"(1.71) | 0.75"(1.90) | 1.0(0.9) |
2.5" |
2519HF 2540TM 2540HF 2540HM |
2.4"(6.1) 2.4"(6.1) 2.4"(6.1) 2.4"(6.1) |
19.0"(48.3) 40.0"(101.6) 40.0"(101.6) 40.0"(101.6) |
0.625"(1.59) 0.75"(1.90) 0.625"(1.59) 0.75"(1.90) |
– 1.0" (2.54) – 1.0 (2.54) |
3.0(1.4) 6.0(2.7) 6.0(2.7) 6.0(2.7) |
4" |
4040TM 4040HM 4040HF |
3.9" (9.9) 3.9" (9.9) 3.9" (9.9) |
40.0" (101.6) 40.0" (101.6) 40.0" (101.6) |
0.75" (1.90) 0.75" (1.90) 0.625" (1.59) |
– 1.0" (2.54) – |
12.0(5.5) 12.0(5.5) 12.0(5.5) |
8" | 8040 | 7.9" (20.1) | 40.0" (101.6) | 1.125" (2.86) | – | 35.0(15.9) |
Recommended Element Cross Flow Rate
Element | Feed Spacer (in mils)
|
||||||||||
1.8" | m3/hr gpm |
0.4 1.8 |
0.5 2.0 |
0.6 2.4 |
0.6 2.5 |
0.6 2.6 |
|||||
2.5" | m3/hr gpm |
1.2 5 |
1.4 6 |
1.6 7 |
1.8 8 |
2.1 9 |
|||||
4" | m3/hr gpm |
2 10 |
4 18 |
5 21 |
5 23 |
6 24 |
|||||
8" | m3/hr gpm |
10 43 |
11 48 |
13 55 |
14 61 |
15 64 |
The recommended cross flow rate will be subject to differential pressure limitations and specific applications.
NF Membrane Area(SQ. FT.)
Element | Feed Spacer (in mils)
|
|||||||||
1812TM | 4 | 3.4 | 2.6 | 2.0 | 1.6 | |||||
2540HF | 35 | 30 | 23 | 17 | 15 | |||||
2540HM | 33 | 28 | 21 | 16 | 14 | |||||
4040HF | 99 | 87 | 68 | 51 | 43 | |||||
4040HM | 96 | 82 | 64 | 50 | 42 | |||||
8040HF | 440 | 380 | 293 | 227 | 193 | |||||
TECHNICAL NOTES
For element sizes not listed, please call or email Synder Filtration for details. We can design an element to fit your exact needs – just specify the element outer diameter (OD) or vessel/housing inner diameter (ID), element inner diameter (ID), and length. Elements are also available with or without a controlled bypass tail. Additional feed spacers are also available. Trials should be conducted to determine optimal application conditions.
Applications
Similar Membranes
questions? Fill out this form. We’ll contact you within 24 hours!
Resources
MEMBRANE RESOURCES
- Definition of a Membrane
- Membrane Materials: Organic vs. Inorganic
- Pressure-Driven Membrane Filtration Processes
- Concentration Polarization in Pressure-Driven Processes
- Degrees of Membrane Separation
- Flux Behavior in Membrane Processes
Module Configurations & Processes
-> View all membrane resources
TUTORIALS