LV (PES 200KDA) – PHT

Specsheets

Membrane Specsheets

Questions? CONTACT US +1 (707) 451-6060

vapPHT Sanitary Ultrafiltration Spiral-Wound Element:
LV (PES 200kDa)

Synder Filtration’s PHT Series of Ultrafiltration Elements offer exceptional physical and chemical durability, in the same wide range of MWCO’s as our standard UF elements. Contact us today to learn more about our complete line of membrane products and services.



PHT SERIES BENEFITS

  • Conforms to 3-A, FDA, and USDA sanitary standards
  • Elimination of chlorine during CIP with hot sanitation
  • High resistance to pH, temperature, & fouling
  • Customizable dimensions for unique housings

COMMON APPLICATIONS

  • Corn wet milling

Element Specifications

ropedma
recfrtneds

RECOMMENDED OPERATING PARAMETERS

Operating Parameters
Maximum Temperature 60°C (140°F)
pH Range @ Max Temperature 2-10
pH Range @ Ambient Temperature 2-10.5

 

Pressure PSI Bar
Max Inlet Pressure 120 8.3
Min Outlet Pressure 10 0.7
Max Differential Pressure per Element 18 1.2
Max Permeate Backpressure 5 0.3

Note: Soft start on boost pumps required to rninimize pressure/flow shocks to elements.

 

Cleaning Parameters
Maximum Temperature (Short term <30min) 85°C (185°F)
pH Range @ Max Temperature 2-11
pH Range @ Ambient Temperature 2-12.5

 

Chlorine Norm PPM Max PPM
Free Chlorine During Operation 0 <0.1
Chlorine During CIP at pH10.8-11.0 and 50°C 150 180

Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.

 

Dairy Product Total Solids Limits Feed Spacer (in mils)

31 46 65 80
Sweet Whey Max. T.S. 15 25 28 30
Acid Whey Max. T.S. 15 24 26 28
Skim Milk Max. T.S. 14 24 26 28
Whole Milk Max. T.S. 15 30 33 35

Note: Trials should be made to determine temperature and viscosity effects.

 

Element Dimensions

Element Model No. Diameter (B) in Length (A) in P.W.T. ID
1.8" 1812F 1.8 12 0.63
2.5" 2519
2540F
2540M*
2.5
2.5
2.5
19.25
40
38
0.63
0.63
0.75
3.8" 3838
3838.75
3850
3938.75
3.8
3.8
3.8
4.0
38
38.75
50
38.75
0.83
0.83
0.83
0.63
4.3" 4333
4335
4335.5
4336
4338
4.3
4.3
4.3
4.3
4.3
33
35
35.5
36
38
0.83
0.83
0.83
0.83
0.83
5.8" 5838 5.8 38 1.14
6.3" 6338
6324
6.3
6.3
38
24
1.14
1.14
6.4" 6438
6424
6.4
6.4
38
24
1.14
1.14
7.8" 7838
7824
7.8
7.8
38
24
1.14
1.14
8" 8038
8040
8238
8240
8338
8340
8.0
8.0
8.2
8.2
8.3
8.3
38
40
38
40
38
40
1.14
1.14
1.14
1.14
1.14
1.14
9.8" 9838 9.8 38 1.14
10" 10338 10.3 38 1.14

*1″ permeate tube extensions (0.75″ OD)

 

Recommended Element Cross Flow Rate

Element Feed Spacer (in miles)

24 31 46 65 80
1.8" m3/hr
gpm
1
4
1
5
1
6
2
7
2
7
2.5" m3/hr
gpm
2
9
2
10
3
11
3
12
3
13
3.8" m3/hr
gpm
5
22
6
25
7
29
8
33
8
35
4.3" m3/hr
gpm
6
29
7
32
9
38
10
44
10
46
5.8" m3/hr
gpm
12
51
13
59
16
69
18
78
19
83
6.3" m3/hr
gpm
15
65
17
74
20
88
22
99
24
105
8" m3/hr
gpm
21
94
24
107
29
128
33
143
35
154
10" m3/hr
gpm
42
184
48
213
57
250
64
283
68
299

The recommended cross flow rate will be subject to differential pressure limitations and specific applications. Please consult Synder Filtration if additional information is needed.


Synder_SpecificMembranes-img1


Membrane Area(SQ. FT.)

Element Model No. Feed Spacer (in mils)

24 31 46 65 80
1.8" 1812F N/A 3.6 N/A N/A N/A
2.5" 2519
2540F
2540M
15
34
35
13
29
30
10
22
23
N/A
N/A
N/A
N/A
N/A
N/A
3.8" 3838
3838.75
3850
3938.75
85
86
100
102
72
74
84
89
58
59
70
69
46
47
52
53
38
39
46
47
4.3" 4333
4335
4335.5
4336
4338
99
105
107
108
115
86
91
93
94
100
66
71
72
73
77
53
56
57
58
62
44
47
48
49
52
5.8" 5838 210 184 147 114 96
6.3" 6324
6338
150
246
134
220
107
176
83
136
70
115
6.4" 6424
6438
157
258
140
230
112
184
83
136
74
122
7.8" 7824
7838
242
396
210
344
166
273
132
216
110
180
8" 8038
8040
8238
8240
8338
8340
414
414
441
441
450
450
368
368
384
384
400
400
287
287
302
302
311
311
225
225
238
238
245
245
189
189
201
201
207
207
9.8" 9838 N/A 564 440 351 296
10" 10338 N/A 620 492 386 326

 

TECHNICAL NOTES

For element sizes not listed, please call or email Synder Filtration for details. We can design an element to fit your exact needs – just specify the element outer diameter (OD) or vessel/housing inner diameter (ID), element inner diameter (ID), and length. Elements are also available with or without a controlled bypass tail. Additional feed spacers are also available. Trials should be conducted to determine optimal application conditions.

 

Element Descriptions

Model No. OD (in.) L (in.) ID* (in.) Weight (lb) Weight (kg)
1812F 1.8 12 0.63 1.0 0.5
2519
2540F
2540M*
2.5
2.5
2.5
19.25
40
38
0.63
0.63
0.75
2
4
4
0.9
1.8
1.8
3838
3838.75
3850
3938.75
3.8
3.8
3.8
4.0
38
38.75
50
38.75
0.83
0.83
0.83
0.63
10
10
13
10
4.5
4.5
5.9
4.5
4333
4335
4335.5
4336
4338
4.3
4.3
4.3
4.3
4.3
33
35
35.5
36
38
0.83
0.83
0.83
0.83
0.83
11
11
11
11
12
5.0
5.2
5.2
5.2
5.4
5838 5.8 38 1.14 15 7
6338
6324
6438
6424
6.3
6.3
6.4
6.4
38
24
38
24
1.14
1.14
1.14
1.14
16
17
29
18
7
7.7
13.2
8.2
7838
7824
7.8
7.8
38
24
1.14
1.14
40
26
18.2
11.8
8038
8040
8238
8240
8338
8340
8.0
8.0
8.2
8.2
8.3
8.3
38
40
38
40
38
40
1.14
1.14
1.14
1.14
1.14
1.14
38
39
38
40
40
40
17.2
17.7
17.2
18
18
18
9838 9.8 38 1.14 42 19.1
10338 10.3 38 1.14 50 22.7

*1″ permeate tube extensions (0.75″ OD)
Note: Different diameters are available. Please specify your requirements when ordering. Specifications are subject to change without notice.

Contact Us