PHT Sanitary Ultrafiltration Spiral-Wound Element:
SM (PES 20kDa)
Synder Filtration’s PHT Series of Ultrafiltration Elements offer exceptional physical and chemical durability, in the same wide range of MWCO’s as our standard UF elements. Contact us today to learn more about our complete line of membrane products and services.
SM is the intermediary PES-based ultrafiltration membrane between Synder’s ST and MK, and is also commonly used for specialty protein separation. Along with the other sanitary UF membranes, SM conforms to 3-A, FDA, and USDA sanitary standards and provides good resistance to pH and temperature as well as a high resistance to fouling. Other common applications skim milk protein concentrate/isolate production and beverage clarification.
PHT SERIES BENEFITS
- Conforms to 3-A, FDA, and USDA sanitary standards
- Elimination of chlorine during CIP with hot sanitation
- High resistance to pH, temperature, & fouling
- Customizable dimensions for unique housings
COMMON APPLICATIONS
- Specialty protein separation
- Skim milk protein concentrate & isolate production
- Beverage clarification
Element Specifications
RECOMMENDED OPERATING PARAMETERS
Operating Parameters | |
Maximum Temperature | 60°C (140°F) |
pH Range @ Max Temperature | 2-10 |
pH Range @ Ambient Temperature | 2-10.5 |
Pressure | PSI | Bar |
Max Inlet Pressure | 120 | 8.3 |
Min Outlet Pressure | 10 | 0.7 |
Max Differential Pressure per Element | 18 | 1.2 |
Max Permeate Backpressure | 5 | 0.3 |
Note: Soft start on boost pumps required to rninimize pressure/flow shocks to elements.
Cleaning Parameters | |
Maximum Temperature (Short term <30min) | 85°C (185°F) |
pH Range @ Max Temperature | 2-11 |
pH Range @ Ambient Temperature | 2-12.5 |
Chlorine | Norm PPM | Max PPM |
Free Chlorine During Operation | 0 | <0.1 |
Chlorine During CIP at pH10.8-11.0 and 50°C | 150 | 180 |
Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above.
Dairy Product Total Solids Limits | Feed Spacer (in mils)
|
|||||||
Sweet Whey Max. T.S. | 15 | 25 | 28 | 30 | ||||
Acid Whey Max. T.S. | 15 | 24 | 26 | 28 | ||||
Skim Milk Max. T.S. | 14 | 24 | 26 | 28 | ||||
Whole Milk Max. T.S. | 15 | 30 | 33 | 35 |
Note: Trials should be made to determine temperature and viscosity effects.
Element Dimensions
Element | Model No. | Diameter (B) in | Length (A) in | P.W.T. ID |
1.8″ | 1812F | 1.8 | 12 | 0.63 |
2.5″ | 2519 2540F 2540M* |
2.5 2.5 2.5 |
19.25 40 38 |
0.63 0.63 0.75 |
3.8″ | 3838 3838.75 3850 3938.75 |
3.8 3.8 3.8 4.0 |
38 38.75 50 38.75 |
0.83 0.83 0.83 0.63 |
4.3″ | 4333 4335 4335.5 4336 4338 |
4.3 4.3 4.3 4.3 4.3 |
33 35 35.5 36 38 |
0.83 0.83 0.83 0.83 0.83 |
5.8″ | 5838 | 5.8 | 38 | 1.14 |
6.3″ | 6338 6324 |
6.3 6.3 |
38 24 |
1.14 1.14 |
6.4″ | 6438 6424 |
6.4 6.4 |
38 24 |
1.14 1.14 |
7.8″ | 7838 7824 |
7.8 7.8 |
38 24 |
1.14 1.14 |
8″ | 8038 8040 8238 8240 8338 8340 |
8.0 8.0 8.2 8.2 8.3 8.3 |
38 40 38 40 38 40 |
1.14 1.14 1.14 1.14 1.14 1.14 |
9.8″ | 9838 | 9.8 | 38 | 1.14 |
10″ | 10338 | 10.3 | 38 | 1.14 |
*1″ permeate tube extensions (0.75″ OD)
Recommended Element Cross Flow Rate
Element | Feed Spacer (in miles)
|
||||||||||
1.8″ | m3/hr gpm |
1 4 |
1 5 |
1 6 |
2 7 |
2 7 |
|||||
2.5″ | m3/hr gpm |
2 9 |
2 10 |
3 11 |
3 12 |
3 13 |
|||||
3.8″ | m3/hr gpm |
5 22 |
6 25 |
7 29 |
8 33 |
8 35 |
|||||
4.3″ | m3/hr gpm |
6 29 |
7 32 |
9 38 |
10 44 |
10 46 |
|||||
5.8″ | m3/hr gpm |
12 51 |
13 59 |
16 69 |
18 78 |
19 83 |
|||||
6.3″ | m3/hr gpm |
15 65 |
17 74 |
20 88 |
22 99 |
24 105 |
|||||
8″ | m3/hr gpm |
21 94 |
24 107 |
29 128 |
33 143 |
35 154 |
|||||
10″ | m3/hr gpm |
42 184 |
48 213 |
57 250 |
64 283 |
68 299 |
The recommended cross flow rate will be subject to differential pressure limitations and specific applications. Please consult Synder Filtration if additional information is needed.
Membrane Area(SQ. FT.)
Element | Model No. | Feed Spacer (in mils)
|
|||||||||
1.8″ | 1812F | N/A | 3.6 | N/A | N/A | N/A | |||||
2.5″ | 2519 2540F 2540M |
15 34 35 |
13 29 30 |
10 22 23 |
N/A N/A N/A |
N/A N/A N/A |
|||||
3.8″ | 3838 3838.75 3850 3938.75 |
85 86 100 102 |
72 74 84 89 |
58 59 70 69 |
46 47 52 53 |
38 39 46 47 |
|||||
4.3″ | 4333 4335 4335.5 4336 4338 |
99 105 107 108 115 |
86 91 93 94 100 |
66 71 72 73 77 |
53 56 57 58 62 |
44 47 48 49 52 |
|||||
5.8″ | 5838 | 210 | 184 | 147 | 114 | 96 | |||||
6.3″ | 6324 6338 |
150 246 |
134 220 |
107 176 |
83 136 |
70 115 |
|||||
6.4″ | 6424 6438 |
157 258 |
140 230 |
112 184 |
83 136 |
74 122 |
|||||
7.8″ | 7824 7838 |
242 396 |
210 344 |
166 273 |
132 216 |
110 180 |
|||||
8″ | 8038 8040 8238 8240 8338 8340 |
414 414 441 441 450 450 |
368 368 384 384 400 400 |
287 287 302 302 311 311 |
225 225 238 238 245 245 |
189 189 201 201 207 207 |
|||||
9.8″ | 9838 | N/A | 564 | 440 | 351 | 296 | |||||
10″ | 10338 | N/A | 620 | 492 | 386 | 326 |
TECHNICAL NOTES
For element sizes not listed, please call or email Synder Filtration for details. We can design an element to fit your exact needs – just specify the element outer diameter (OD) or vessel/housing inner diameter (ID), element inner diameter (ID), and length. Elements are also available with or without a controlled bypass tail. Additional feed spacers are also available. Trials should be conducted to determine optimal application conditions.
Element Descriptions
Model No. | OD (in.) | L (in.) | ID* (in.) | Weight (lb) | Weight (kg) |
1812F | 1.8 | 12 | 0.63 | 1.0 | 0.5 |
2519 2540F 2540M* |
2.5 2.5 2.5 |
19.25 40 38 |
0.63 0.63 0.75 |
2 4 4 |
0.9 1.8 1.8 |
3838 3838.75 3850 3938.75 |
3.8 3.8 3.8 4.0 |
38 38.75 50 38.75 |
0.83 0.83 0.83 0.63 |
10 10 13 10 |
4.5 4.5 5.9 4.5 |
4333 4335 4335.5 4336 4338 |
4.3 4.3 4.3 4.3 4.3 |
33 35 35.5 36 38 |
0.83 0.83 0.83 0.83 0.83 |
11 11 11 11 12 |
5.0 5.2 5.2 5.2 5.4 |
5838 | 5.8 | 38 | 1.14 | 15 | 7 |
6338 6324 6438 6424 |
6.3 6.3 6.4 6.4 |
38 24 38 24 |
1.14 1.14 1.14 1.14 |
16 17 29 18 |
7 7.7 13.2 8.2 |
7838 7824 |
7.8 7.8 |
38 24 |
1.14 1.14 |
40 26 |
18.2 11.8 |
8038 8040 8238 8240 8338 8340 |
8.0 8.0 8.2 8.2 8.3 8.3 |
38 40 38 40 38 40 |
1.14 1.14 1.14 1.14 1.14 1.14 |
38 39 38 40 40 40 |
17.2 17.7 17.2 18 18 18 |
9838 | 9.8 | 38 | 1.14 | 42 | 19.1 |
10338 | 10.3 | 38 | 1.14 | 50 | 22.7 |
*1″ permeate tube extensions (0.75″ OD)
Note: Different diameters are available. Please specify your requirements when ordering. Specifications are subject to change without notice.
Applications
Similar Membranes
questions? Fill out this form. We’ll contact you within 24 hours!
Resources
MEMBRANE RESOURCES
- Definition of a Membrane
- Membrane Materials: Organic vs. Inorganic
- Pressure-Driven Membrane Filtration Processes
- Concentration Polarization in Pressure-Driven Processes
- Degrees of Membrane Separation
- Flux Behavior in Membrane Processes
Module Configurations & Processes
-> View all membrane resources
TUTORIALS